Determination of toxic and essential elements in children's blood with inductively coupled plasma-mass spectrometry

Ali Bazzi1, Jerome O Nriagu, Aaron M Linder

  • 1University of Michigan-Dearborn, Department of Natural Sciences, 4901 Evergreen Road, Dearborn, MI 48128-1491, USA. abazz@umd.umich.edu

Insights

This study measured essential and toxic elements in South African children

Area of Science:

  • Environmental Health
  • Pediatric Toxicology
  • Analytical Chemistry

Background:

  • Low blood lead levels (<50 µg/L) may affect child neurobehavior.
  • Essential element deficiencies can increase lead toxicity.
  • Manganese compounds in gasoline necessitate monitoring of heavy metals.

Purpose of the Study:

  • To determine blood concentrations of lead, manganese, and other elements in South African school children.
  • To assess potential toxic metal exposure and essential nutrient status.
  • To establish baseline data for pediatric heavy metal and element levels.

Main Methods:

  • Multi-element analysis of blood samples using inductively coupled plasma-mass spectrometry (ICP-MS).
  • Open digestion with nitric acid/hydrogen peroxide followed by dilution.
  • Validation using reference materials (Seronorm) and human blood samples.

Main Results:

  • Average blood lead: 56.4 µg/L; Arsenic: 1.53 µg/L; Manganese: 8.48 µg/L.
  • Cobalt, copper, selenium, and chromium levels were higher than in other studies.
  • Zinc levels were lower than previously reported.

Conclusions:

  • Blood lead levels were consistent with some lower reported values.
  • Arsenic and manganese levels were generally lower than literature values.
  • Observed variations in essential and toxic element concentrations highlight regional differences and potential health implications.

Related Concept Videos

Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Inductively Coupled Plasma&#8211;Mass Spectrometry (ICP&#8211;MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...