Propagation of vibration caused by electrical excitation in the normal human heart
1Graduate Schools of Engineering and Biomedical Engineering, Tohoku University, Sendai, Japan. hkanai@ecei.tohoku.ac.jp
Abstract:
The ability to noninvasively detect regional dynamic myocardial damage related to action potentials and mechanical properties affected by heart disease is of great clinical importance. Though there are invaluable clinical tools for diagnosis of a broad range of cardiac conditions, such myocardial properties cannot be evaluated. We have previously shown that pulsive vibration occurs on the myocardium after electrical stimulation of an isolated heart. In this study, using a novel technique for ultrasonic measurement of the myocardial motion, we detected pulsive vibrations spontaneously caused by electrical excitation and by valve closure. Using a sparse sector scan, the vibrations were measured almost simultaneously at about 10,000 points set in the heart wall at a high temporal resolution. The consecutive spatial distributions of the phase of the vibrations revealed wave propagation along the wall in healthy subjects for the first time in vivo. At around the time of the Q-wave of the electrocardiogram, the propagation started from the interventricular septum and extended to both the base and apical sides of the heart with a speed of 1 m/s, which corresponds to the propagation of electrical excitation from the Purkinje fiber-myocyte junction in the interventricular septum. Other vibrations then propagated from the base at several m/s, although some of them had dispersion properties. These are shear waves caused by the mitral-valve closure, corresponding to the first heart sound. These phenomena have potential for detection of regional myocardial tissue damage related to propagation of the action potentials and regional myocardial viscoelasticity.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Mechanism of Cardiac Arrhythmias
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...