Effectiveness of transobturator tape in women with decreased urethral mobility

Steven Minaglia1, Rebecca Urwitz-Lane, Micheline Wong

  • 1Division of Female Pelvic Medicine and Reconstructive Surgery, Department of Obstetrics and Gynecology, Keck School of Medicine, University of Southern California, Los Angeles, USA. minaglia@hawaii.edu

Abstract

Related Concept Videos

Decreasing Function01:27

Decreasing Function

A decreasing function describes a relationship where the output consistently declines as the input increases. This means that for any two input values, if one is greater than the other, the corresponding output is smaller. Mathematically, a function f is decreasing on an interval I if for every x1 < x2​ in I, f (x1) > f (x2). This type of behavior is visually identified on a graph that slopes downward from left to right.The nature of a function can be analyzed by calculating...
309
Errors in Taping01:18

Errors in Taping

Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
363
Taping Over Different Ground Profiles01:12

Taping Over Different Ground Profiles

Taping over varying ground profiles requires careful adaptation to achieve accurate measurements. On smooth, level ground with minimal vegetation, the tape can rest directly on the ground. Here, the taping team, typically consisting of a head and a rear tapeman, coordinates their positions with clear communication. The rear tapeman holds the tape at the starting point and guides the head tapeman toward a range pole placed beyond the endpoint, using hand or voice signals to ensure alignment.On...
404
Distance Measurements by Taping01:18

Distance Measurements by Taping

Tapes are essential in surveying for accurate, durable, and short-distance measurements. Made from lightweight, nylon-coated steel, they offer flexibility and strength for rugged outdoor use. The nylon coating protects against rust and wear, extending the tape's life. Standard lengths, around 30 meters, are marked in meters and millimeters for precision.Surveyors select tapes based on site conditions and accuracy needs. Lightweight, nylon-coated tapes are commonly used for ease of handling and...
475
Decreased Body Temperature01:29

Decreased Body Temperature

A decreased body temperature can occur in patients with hypothermia and frostbite. Heat loss with extended cold exposure overpowers the body's ability to create heat, resulting in hypothermia. Core temperature readings help classify hypothermia. Mild hypothermia is temperatures between 32 °C (89.6 °F) and 35°C (95 °F) and is caused by impaired thermoregulation. Moderate hypothermia is temperatures between 28 C (82.4 °F) and 32 °C (89.6 °F) caused by...
1.1K
Decreased pulse rate01:14

Decreased pulse rate

Bradycardia is a medical condition in which the heart rate is slower than normal. It occurs when the heart's natural pacemaker, the sinus node, generates slower electrical impulses than the standard rhythm. In adults, bradycardia is diagnosed when the pulse rate falls below 60 beats per minute, indicating a deviation from the normal heart rate range.
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
918