Related Experiment Video
Updated: Jun 25, 2026

Measurement of Tumor T2* Relaxation Times after Iron Oxide Nanoparticle Administration
Published on: May 19, 2023
R2* magnetic resonance imaging of the liver in patients with iron overload
Jane S Hankins1, M Beth McCarville, Ralf B Loeffler
1Departments of Hematology, St Jude Children's Research Hospital, Memphis, TN 38105-3678, USA. jane.hankins@stjude.org
Abstract:
R2* magnetic resonance imaging (R2*-MRI) can quantify hepatic iron content (HIC) by noninvasive means but is not fully investigated. Patients with iron overload completed 1.5T R2*-MRI examination and liver biopsy within 30 days. Forty-three patients (sickle cell anemia, n = 32; beta-thalassemia major, n = 6; and bone marrow failure, n = 5) were analyzed: median age, 14 years, median transfusion duration, 15 months, average (+/-SD) serum ferritin 2718 plus or minus 1994 ng/mL, and average HIC 10.9 plus or minus 6.8 mg Fe/g dry weight liver. Regions of interest were drawn and analyzed by 3 independent reviewers with excellent agreement of their measurements (intraclass correlation coefficient = 0.98). Ferritin and R2*-MRI were weakly but significantly associated (range of correlation coefficients among the 3 reviewers, 0.41-0.48; all P < .01). R2*-MRI was strongly associated with HIC for all 3 reviewers (correlation coefficients, 0.96-0.98; all P < .001). This high correlation confirms prior reports, calibrates R2*-MRI measurements, and suggests its clinical utility for predicting HIC using R2*-MRI. This study was registered at www.clinicaltrials.gov as #NCT00675038.
Insights
R2* magnetic resonance imaging (R2*-MRI) accurately quantifies hepatic iron content (HIC). This noninvasive method shows strong correlation with liver biopsy results, confirming its clinical utility for managing iron overload.
Area of Science:
- Medical Imaging
- Hepatology
- Hematology
Background:
- Noninvasive quantification of hepatic iron content (HIC) is crucial for managing iron overload.
- R2* magnetic resonance imaging (R2*-MRI) shows potential for assessing HIC but requires further investigation.
Purpose of the Study:
- To investigate the accuracy and clinical utility of R2*-MRI for quantifying HIC in patients with iron overload.
Main Methods:
- 43 patients with iron overload underwent 1.5T R2*-MRI and liver biopsy within 30 days.
- Regions of interest were analyzed by 3 independent reviewers, assessing inter-reviewer agreement.
- Correlation between R2*-MRI, serum ferritin, and HIC was evaluated.
Main Results:
- R2*-MRI measurements showed excellent inter-reviewer agreement (ICC = 0.98).
- R2*-MRI demonstrated a strong correlation with HIC (correlation coefficients, 0.96-0.98; P < .001).
- A weaker but significant association was found between serum ferritin and R2*-MRI (correlation coefficients, 0.41-0.48; P < .01).
Conclusions:
- R2*-MRI is a reliable and accurate noninvasive method for quantifying hepatic iron content.
- The findings support the clinical utility of R2*-MRI for predicting HIC in patients with iron overload.
- This study calibrates R2*-MRI measurements and confirms prior reports on its efficacy.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...