Related Experiment Video
Updated: Jun 25, 2026

HPLC Measurement of the DNA Oxidation Biomarker, 8-oxo-7,8-dihydro-2’-deoxyguanosine, in Cultured Cells and Animal Tissues
Published on: August 1, 2015
Electrochemical behaviors of guanosine on carbon ionic liquid electrode and its determination
Wei Sun1, Yuanyuan Duan, Yinzhuo Li
1Key Laboratory of Eco-Chemical Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, 53 Zhenzhou Road, Qingdao 266042, China. sunwei@qust.edu.cn
Abstract:
The electrochemical behaviors of guanosine on the ionic liquid of N-butylpyridinium hexafluorophosphate (BPPF(6)) modified carbon paste electrode (CPE) was studied in this paper and further used for guanosine detection. Guanosine showed an adsorption irreversible oxidation process on the carbon ionic liquid electrode (CILE) with the oxidation peak potential located at 1.12 V (vs. SCE) in a pH 4.5 Britton-Robinson (B-R) buffer solution. Compared with that on the traditional carbon paste electrode, small shift of the oxidation peak potentials appeared but with a great increment of the oxidation peak current on the CILE, which was due to the presence of ionic liquid in the modified electrode adsorbed the guanosine on the surface and promoted the electrochemical response. The electrochemical parameters such as the electron transfer coefficient (alpha), the electron transfer number (n), and the electrode reaction standard rate constant (k(s)) were calculated as 0.74, 1.9 and 1.26 x 10(-4)s(-1), respectively. Under the optimal conditions the oxidation peak current showed a good linear relationship with the guanosine concentration in the range from 1.0 x 10(-6) to 1.0 x 10(-4)mol/L by cyclic voltammetry with the detection limit of 2.61 x 10(-7)mol/L (3sigma). The common coexisting substances showed no interferences to the guanosine oxidation. The CILE showed good ability to distinguish the electrochemical response of guanosine and guanine in the mixture solution. The urine samples were further detected by the proposed method with satisfactory results.
Related Concept Videos
Electrogravimetric Analysis: Overview
To test the completeness of the...
Electrodeposition
Electrodeposition can...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Voltammetric Techniques: Cyclic Voltammetry
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Voltammetric Techniques: Linear-Scan (E vs Time)

