Related Experiment Video
Updated: Jun 25, 2026

Array Tomography Workflow for the Targeted Acquisition of Volume Information using Scanning Electron Microscopy
Published on: July 15, 2021
Taguchi OA16 orthogonal array design for the optimization of cloud point extraction for selenium determination in
Mahnaz Ghambarian1, Yadollah Yamini, Abolfazl Saleh
1Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, P.O. Box: 14115-175, Tehran, Iran.
Abstract:
Orthogonal array design (OAD) was applied for the first time to optimize cloud point extraction (CPE) conditions for Se(IV) determination by electrothermal atomic absorption spectrometry (ETAAS) in environmental and biological samples. Selenium was reacted with o-phenylenediamine to form piazselenol in an acidic medium (pH 2). Using Triton X-114, as surfactant, piazselenol was quantitatively extracted into small volume (about 30 microL) of the surfactant-rich phase after centrifugation. Five relevant factors, i.e. surfactant concentration, pH, ionic strength, equilibrium time and temperature were selected and the effects of each factor were studied at four levels on the extraction efficiency of Se(IV) and optimized. The statistical analysis revealed that the most important factors contributing to the extraction efficiency are ionic strength, pH and percent of surfactant. Based on the results obtained from the analysis of variance (ANOVA), the optimum conditions for extraction were established as: pH 6; vial temperature=50 degrees C; extraction time=7 min and 0.3% (w/v) of Triton X-114. The method was permitted to obtain a detection limit of 0.09 ng mL(-1) and two linear calibration ranges from 0.6 to 1.0 and 1.0 to 80.0 ng mL(-1) Se. The precision (%RSD) of the extraction and determination for the six replicates of Se at 20 ng mL(-1) was better than 3.6% and the enrichment factor of 63.5 was achieved. The studied analyte was successfully extracted and determined with high efficiency using cloud point extraction method in water and biological matrices.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
11:27A Package of Established Analytical Tools to Investigate the Solid-State Alteration of Lipid-Based Excipients
Published on: August 9, 2022
Related Concept Videos
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Interference
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...