Related Experiment Video
Updated: Jun 25, 2026

Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
Improvement of autohydrogenotrophic nitrite reduction rate through optimization of pH and sodium bicarbonate dose in
Shahin Ghafari1, Masitah Hasan, Mohamed Kheireddine Aroua
1Department of Chemical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia.
Abstract:
Accumulation of nitrite intermediate in autohydrogenotrophic denitrification process has been a challenging difficulty to tackle. This study showed that further growth of "true denitrifying" bacteria and adaptation to nitrite led to a faster reduction of nitrite than nitrate as a solution to circumvent nitrite accumulation. Moreover, two effective parameters namely pH and bicarbonate dose were optimized in order to achieve a better reduction rate. Sodium bicarbonate dose ranging from 20 to 2000 mg/L and pH in the range of 6.5-8.5 was selected to be examined employing 0.2 g MLVSS/L of reacclimatized denitrifying bacteria. Eleven runs of experiments were designed considering the interactive effect of these two operative parameters. A fairly close reduction time less than 4.5 h (>22.22 mg NO2(-)-N/g MLVSS/h) was gained for the pH range between 7 and 8. The highest specific nitrite reduction rate at 25 mg NO2(-)-N/g MLVSS/h was achieved applying 1000 mg NaHCO3/L at pH 7.5 and 8. The pH was found to be the leading parameter and bicarbonate as the less effective parameter on nitrite reduction removal. Central composite design (CCD) and response surface design (RSM) were employed to develop a model as well as define the optimum condition. Using the experimental data, the developed quadratic model predicted optimum condition at pH 7.8 and sodium bicarbonate dose 1070 mg/L upon which denitrifiers managed to accomplish reduction within 3.5 h and attained the specific degradation rate of 28.57 mg NO2(-)-N/g MLVSS/h.
Related Concept Videos
Methods of Medium Optimization
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration of Polyprotic Base with a Strong Acid
Metabolism of Chemolithotrophs
Bioreactor Controls-I

