Tree Core Analysis with X-ray Computed Tomography
Published on: September 22, 2023
Non-invasive and rapid analysis for observation of internal structure of press-coated tablet using X-ray computed
Yoshihiro Tokudome1, Hiroyuki Ohshima, Makoto Otsuka
1Faculty of Pharmacy, Institute of Pharmaceutical Sciences, Musashino University Nishi-Tokyo, Tokyo, Japan.
Background:
Since the internal structure of a tablet can be measured without destruction of the sample by X-ray computed tomography (CT), it could be applied to quality control of tablets during the manufacturing process.
Aim:
A novel, fast, noninvasive tablet observation method was developed to evaluate the internal structure of commercial press-coated tablets by using X-ray CT.
Method:
Thirty-two CT image slices of four kinds of commercial press-coated tablets (tablets A, B, C, and D) were measured 300 m interval between edges of the tablet by using an X-ray CT. The thinnest layer thickness of the tablets and distance between centers of gravity (DCG) of tables were calculated.
Results:
The order of the TLT of the tablets was tablet B > tablet C > tablet D > tablet A. The result indicated that the order of DCG was tablet A > tablet D > tablet C > tablet B. Noninvasive observation of the internal structure of commercial, press-coated tablets by X-ray CT has been demonstrated to be useful in quality control of production.
Conclusion:
The internal structure of press-coated tablets could be observed without pretreatment, without destruction, and very rapidly by X-ray CT.
Related Concept Videos
X-ray Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...