Related Experiment Video
Updated: Apr 29, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Simultaneous determination of nonnutritive sweeteners in foods by HPLC/ESI-MS
1Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha 410081, China.
Abstract:
Nonnutritive sweeteners are the low calorie substances used to replace sugar and other caloric ones. Determination of these sweeteners in foods is important to ensure consistency in product quality. In this study, seven artificial (aspartame, saccharin, acesulfame-K, neotame, sucralose, cyclamate, and alitame) and one natural sweetener (stevioside) were simultaneously determined in different foods using high performance liquid chromatography (HPLC) coupled with electrospray ionization mass spectrometric detection (ESI-MS). The target compounds were quantified using a selective ionization recording (SIR) at m/z 178, 397, 377, 293, 641, 312, 162, and 182 to cyclamate, sucralose, neotame, aspartame, stevioside, alitame, acesulfame-K, and saccharin, respectively, with warfarin sodium (SIR m/z 307) being used as an internal standard. The correlation coefficient of the calibration curve was better than 0.998 (n = 6), in the range of 0.05 to 5.00 microg/mL for cyclamate, 0.30 to 30.0 microg/mL for sucralose, 0.10 to 10.0 microg/mL for neotame, 0.20 to 20.0 microg/mL for aspartame, 0.50 to 15.0 microg/mL for stevioside, 0.08 to 8.00 microg/mL for alitame, 0.10 to 15.0 microg/mL for acesulfame-K, and 0.05 to 5.00 microg/mL for saccharin. The limits of detection (LODs) were below 0.10 microg/mL, whereas the limits of quantification (LOQs) were below 0.30 microg/mL. It is concluded that the method has merits such as high sensitivity, specificity, and simplicity versus the those of the other methods reported in the literature.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors