Related Experiment Video
Updated: Jun 24, 2026

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Dimensional accuracy of upper complete denture bases: the effect of metallic flask closure methods
Rafael Leonardo Xediek Consani1, Marcelo Ferraz Mesquita, Lourenço Correr Sobrinho
1Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas, Sao Paulo, Brazil. rconsani@fop.unicamp.br
Objectives:
To verify the dimensional accuracy of upper complete denture bases under the effect of different methods of metallic flask closure.
Materials And Methods:
Wax record bases were assigned to six groups: 1-2: traditional clamp; 3-4: RS system; and 5-6: flask with screws. Flasks were immediately polymerised or bench stored for 6 h prior to polymerisation. Resin base-cast sets were sectioned at regions corresponding to the canines, first molars and posterior palatal zone. Gap discrepancies were measured at five points: right and left ridge crests, palatal midline, and right and left marginal limits of the flanges. An optical micrometer was used for measurement purposes.
Results:
Data were submitted to anova, and the means compared by Tukey's test (alpha = 0.05). Results revealed significant differences in the flask closure technique, polymerisation time, section, and their interactions. Discrepancy values for the RS system and flask with screws were significantly lower than those related to the traditional clamp, regardless of whether resin polymerisation was immediate or delayed for 6 h.
Conclusions:
Flask closure methods should be considered when the denture base stability and comfort of the patient are being assessed during clinical use of the dentures.

