Related Experiment Video
Updated: Jun 24, 2026

Rapid Scan Electron Paramagnetic Resonance Opens New Avenues for Imaging Physiologically Important Parameters In Vivo
Published on: September 26, 2016
[X-ray-induced DNA double-strand breaks after angiographic examinations of different anatomic regions]
M A Kuefner1, S Grudzenski, S A Schwab
1Radiologisches Institut, Universitätsklinikum Erlangen. michael.kuefner@uk-erlangen.de
Purpose:
The aim of this study was to investigate DNA double-strand breaks (DSBs) in blood lymphocytes as markers of the biological radiation effects in angiography patients.
Materials And Methods:
The method is based on the phosphorylation of the histone variant H 2AX (gamma-H2AX) after formation of DSBs. Blood samples were collected before and up to 24 hours after exposure of 31 patients undergoing angiographies of different body regions. Blood lymphocytes were isolated, fixed, and stained with a specific gamma-H2AX antibody. Distinct foci representing DSBs were enumerated using fluorescence microscopy. Additional in-vitro experiments (10 - 100 mGy) were performed for evaluation of DBS repair.
Results:
15 minutes after the end of fluoroscopy values between 0.01 and 1.50 DSBs per cell were obtained. The DNA damage level normalized to the dose area product was 0.099 (cardiac angiographies), 0.053 (abdominal angiographies), 0.023 (pelvic/leg angiographies) and 0.004 excess foci/cell/mGym (2) (cerebrovascular angiographies). A linear correlation was found between gamma-H2AX foci levels and the dose area product (abdomen: R (2) = 0.96; pelvis/legs: R 2 = 0.71). In-vivo on average 46 % of DSBs disappeared within 1 hour and 70 % within 2.5 hours.
Conclusion:
gamma-H2AX immunofluorescence microscopy is a sensitive and reliable method for the determination of X-ray-induced DSBs during angiography. The DNA damage level depends on the dose, the exposed anatomic region, and the duration/fractionation of the X-ray exposure.
Related Concept Videos
Magnetic Resonance Imaging
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Applications Of NMR In Biology
The...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...

