Related Experiment Video
Updated: Jun 24, 2026

A New Technique for Treating Low-risk Prostate Cancer—Super Active Surveillance
Published on: November 7, 2025
Prospective evaluation of hybrid 18F-fluorodeoxyglucose positron emission tomography/computed tomography in staging
Joost A P Leijte1, Niels M Graafland, Renato A Valdés Olmos
1Department of Urology, The Netherlands Cancer Institute--Antoni van Leeuwenhoek Hospital, Amsterdam, the Netherlands.
Objective:
To prospectively evaluate the performance of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) to detect occult metastasis in patients with clinically node-negative (cN0) penile carcinoma, as there is little information on the use of (18)F-FDG-PET/CT in penile carcinoma.
Patients And Methods:
In 24 patients, scheduled to undergo dynamic sentinel-node biopsy, hybrid PET/CT was used before surgery to assess the nodal status of the cN0-groins. Six of the 24 patients were unilaterally cN0. Thus, 42 cN0-groins were evaluated for occult metastasis using PET/CT. All scans were assessed by two experienced nuclear physicians. The histopathological tumour status of the removed sentinel node was used as the standard of care to evaluate the PET/CT-results.
Results:
Histopathology was tumour-positive in five of the 42 (12%) evaluated cN0-groins, two of which contained only micrometastases (<2 mm). One of the five tumour-positive cN0-groins was correctly predicted on the PET/CT-images. All false-negative PET/CT scans contained metastasis of
Conclusion:
The role of PET/CT in evaluating the groins of patients with cN0 penile cancer appears to be limited, due to its low sensitivity. In this series, only one of the five tumour-positive groins was identified. Surgical staging methods remain necessary at present.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...