Related Experiment Video
Updated: Jun 24, 2026

Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
Electrospray ionization mass spectrometry as a method for studying the high-pressure denaturation of proteins
Piotr Stefanowicz1, Inga Petry-Podgorska, Karolina Kowalewska
1Faculty of Chemistry, University of Wroclaw, 50-383 Wroclaw, Poland. stp@wchuwr.pl
Abstract:
High-pressure denaturation of proteins can provide important information concerning their folding and function. These studies require expensive and complicated equipment. In this paper, we present a new convenient method for studying high-pressure denaturation of proteins combining DHX (deuterium-hydrogen exchange) and electrospray ionization MS. Application of various values of pressure causes different degrees of protein unfolding resulting in molecules with a different number of protons available for exchange with deuterons. After decompression a protein refolds and a certain number of deuterons are trapped within the hydrophobic core of a refolded protein. Redissolving the deuterated protein in an aqueous buffer initiates the DHX of amides located on the protein surface only, which can be monitored under atmospheric pressure by MS. Depending on the degree of deuteration after high-pressure treatment, the DHX kinetics are different and indicate how many deuterons were trapped in the protein after refolding. The dependence of this number on pressure gives information on the denaturation state of a protein. The distribution of deuterium along the sequence of a high-pressure-denatured protein was studied the ECD (electron-capture-induced dissociation) on a Fourier-transform mass spectrometer, enabling the monitoring of high-pressure denaturation with single amino acid resolution.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...