Related Experiment Video
Updated: Jun 24, 2026

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Quantitative evaluation of perchlorethylene in groundwater before and after its oxidation by helical solid sorbent
Marius Draga1, Ionel Ciucanu, Vlad Agotici
1Research in Albi on Particulate Solids: Energy and Environment, School of Mines, Campus Jarlard, 81013 Albi, France.
Abstract:
An integrated method of dynamic extraction of perchloroethylene (PCE) with polydimethylsiloxane (PDMS) helical solid sorbent followed by injection into a gas chromatograph was developed for the determination of the real concentration of PCE in groundwater before and after its degradation by oxidation with KMnO(4). The main parameters (agitation, temperature, salts, pH) that affect the extraction efficiency have been evaluated and optimized. The increase of the extracted amount of PCE due to the presence of the salts could be partially compensated by the opposite effect of the insoluble MnO(2), and of the presence of HCl and the global effect of the matrix would be less important for the reproducibility of the PCE extraction. The quantitative analysis of PCE was carried out with the external standard method using the calibration-curve technique. The limit of detection for PCE was found of 0.05 mg L(-1) using flame ionization detector. The solubility of PCE in water was studied by extraction of PCE with PDMS helical solid sorbent from standard solution with different amounts of PCE added into the same volume of water and was found to decrease with settling time, because the fine droplets created during the agitation of the mixture were slowly merged in drops on the bottle walls and were not transferred into the extraction vial for GC analysis. The limit of solubility was evaluated using a graphical method and was estimated at 224.2+/-15.7 mg L(-1) of PCE in water at 25 degrees C.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Extraction: Advanced Methods