Related Experiment Video
Updated: Jun 24, 2026

2 in 1: One-step Affinity Purification for the Parallel Analysis of Protein-Protein and Protein-Metabolite Complexes
Published on: August 6, 2018
Optimizing the peak capacity per unit time in one-dimensional and off-line two-dimensional liquid chromatography for
Sebastiaan Eeltink1, Sebastiaan Dolman, Remco Swart
1Dionex, Abberdaan 114, 1046 AA Amsterdam, The Netherlands. sebastiaan.eeltink@dionex.com
Abstract:
To obtain the best compromise between peak capacity and analysis time in one-dimensional and two-dimensional (2D) liquid chromatography (LC), column technology and operating conditions were optimized. The effects of gradient time, flow rate, column temperature, and column length were investigated in one-dimensional reversed-phase (RP) gradient nano-LC, with the aim of maximizing the peak per unit time for peptide separations. An off-line two-dimensional LC approach was developed using a micro-fractionation option of the autosampler, which allowed automatic fractionation of peptides after a first-dimension ion-exchange separation and re-injection of the fractions onto a second-dimension RP nano-LC column. Under the applied conditions, which included a preconcentration/desalting time of 5 min, and a column equilibration time of 12.5 min, the highest peak capacity per unit time in the 2D-LC mode was obtained when applying a short (10 min) first-dimension gradient and second-dimension RP gradients of 20 min duration. For separations requiring a maximum peak capacity of 375, one-dimensional LC was found to be superior to the off-line strong cation-exchange/x/RPLC approach in terms of analysis time. Although a peak capacity of 450 could be obtained in one-dimensional LC when applying 120-min gradients on 500-mm long columns packed with 3-mum particles, for separations requiring a peak capacity higher than 375 2D-LC experiments provide a higher peak capacity per unit time. Finally, the potential of off-line 2D-LC coupled to tandem mass spectrometry detection is demonstrated with the analysis of a tryptic digest of a mixture of nine proteins and an Escherichia coli digest.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Principles Of Column Chromatography
Chromatographic Methods: Terminology