Related Experiment Video
Updated: Aug 13, 2026

A Rapid and Specific Microplate Assay for the Determination of Intra- and Extracellular Ascorbate in Cultured Cells
Published on: April 11, 2014
Spectrophotometric determination of ascorbic acid in pharmaceuticals by background correction and flow injection
1Department of Chemistry, Rani Durgavati University, Madhya Pradesh, India.
Abstract:
Background correction has been shown to be an effective and indispensable modification in the spectrophotometric determination of ascorbic acid. The decomposition of ascorbic acid in pharmaceutical samples was carried out by incubation with sodium hydroxide to give products that were insensitive to ultraviolet light. The rapid oxidation in air of ascorbic acid, especially in dilute solutions, was avoided by the use of the flow injection principle for spectrophotometric determination and by employing a carrier stream of an anti-oxidizing nature consisting of 6 micrograms ml(-1) of 2-mercaptoethanol in 0.25% sulphuric acid. The optimized method with a single channel manifold made use of a carrier stream flow rate of 1.1 ml min(-1), an injection volume of 50 microl, a delay coil of 50 cm (0.5 mm i.d.) and detection at 245 nm. The throughput was at least 180 injections h(-1). The proposed flow injection method yielded results for the analysis of 0-20 micrograms ml(-1) of ascorbic acid that were 99-102% (relative standard deviation 0.6% or better) in agreement with those produced by comparable methods involving titration with iodine, chloranil or 2,6-dichlorophenolindophenol [4-(2,6-dichloro-4-hydroxyphenylimino)cyclohexa-2,5-dieno ne], and high-performance liquid chromatography. When the agreement was not good (as low as 14% with respect to the method being compared), this was traced to the presence of substances which are known to interfere in one or other of the methods of comparison.
More Related Videos
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
10:22Improved UPLC-UV Method for the Quantification of Vitamin C in Lettuce Varieties (Lactuca sativa L.) and Crop Wild Relatives (Lactuca spp.)
Published on: June 30, 2020
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...