How to turn your pump-probe instrument into a multidimensional spectrometer: 2D IR and Vis spectroscopies via pulse

Sang-Hee Shim1, Martin T Zanni

  • 1Department of Chemistry, University of Wisconsin-Madison, Madison, WI 53706-1396, USA.

Related Concept Videos

Ultraviolet-Visible (UV-Vis) Spectroscopy09:21

Ultraviolet-Visible (UV-Vis) Spectroscopy

Source: Laboratory of Dr. B. Jill Venton - University of Virginia
Ultraviolet-visible (UV-Vis) spectroscopy is one of the most popular analytical techniques because it is very versatile and able to detect nearly every molecule. With UV-Vis spectroscopy, the UV-Vis light is passed through a sample and the transmittance of light by a sample is measured. From the transmittance (T), the absorbance can be calculated as A=-log (T). An absorbance spectrum is obtained that shows the absorbance of a...
642.6K
UV-Vis Spectroscopy of Dyes09:52

UV-Vis Spectroscopy of Dyes

Source: Lara Al Hariri and Ahmed Basabrain at the University of Massachusetts Amherst, MA, USA
47.3K
UV-Vis Spectroscopy of Dyes03:59

UV-Vis Spectroscopy of Dyes

Source: Lara Al Hariri at the University of Massachusetts Amherst, MA, USA
9.9K
UV-Vis Spectroscopy of Dyes04:55

UV-Vis Spectroscopy of Dyes

Absorbance
When light interacts with a substance, a portion of the light is absorbed while the rest is either reflected or transmitted through it. Substances that we perceive as having a color reflect light in the visible range. The color of the substance that we are able to see depends on which wavelength of light is reflected. A substance that we perceive as blue reflects light in the blue range (430 – 480 nm) of the visible spectrum. According to the color wheel, the same substance absorbs...
150.3K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.4K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.7K