Related Experiment Video
Updated: Jun 24, 2026

Protein Digestion, Ultrafiltration, and Size Exclusion Chromatography to Optimize the Isolation of Exosomes from Human Blood Plasma and Serum
Published on: April 13, 2018
Analysis of low molecular weight plasma proteins using ultrafiltration and large gel two-dimensional electrophoresis
Woon-Won Jung1, Sohee Phark, Sangnam Oh
1Department of Clinical Pathology, College of Health Science, Korea University Sungbuk-Ku, Seoul, Korea.
Abstract:
In this study, various solvent systems were applied to obtain a high and consistent recovery rate of low molecular weight plasma proteins (LMPP) from human plasma. A buffer system containing 7 M urea, 2 M thiourea, 25 mM NH(4)HCO(3) + 20% ACN (pH 8.2) produced the highest recovery rate of LMPP. To validate the recovery of cut off membrane (COM) obtained using the urea buffer system, 27 different 30 kDa COMs were used to prepare the LMPP sample which were then subjected to 1-D SDS-PAGE. Statistical analysis showed that the buffer system with COM produced a consistent the recovery of LMPP. In addition, 2-DE analysis was also conducted to determine the relative intensity of each protein spot. When molecular weight ranges over 30 kDa and under 30 kDa were evaluated, 953 and 587 protein spots were observed in the gels, respectively, resulting in a total of 1540 protein spots being resolved. Identification of the major proteins were then performed using a nano-LC/MS system comprised of an HPLC system and an ESI-quadrupole IT MS equipped with a nano-ESI source.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...