Post-analytical errors with portable glucose meters in the hospital setting
1Department of Laboratory Medicine, University-Hospital of Padova, Italy. paolo.carraro@sanita.padova.it
Summary
Point-of-care testing (POCT) for blood glucose offers rapid results for critical patients. However, manual data transcription in patient records shows high error rates, though no adverse events were linked to these POCT errors.
Area of Science:
- Clinical Chemistry
- Medical Diagnostics
- Patient Safety
Background:
- Point-of-care testing (POCT) for blood glucose is crucial for rapid patient monitoring in critical conditions.
- Limited literature exists on the reliability and safety of POCT, particularly concerning the post-analytical phase.
Purpose of the Study:
- To investigate the type, frequency, and clinical risks of errors in the post-analytical phase of blood glucose POCT.
- To evaluate manual data transcription of POCT results in a hospital setting.
Main Methods:
- Analysis of 1966 blood glucose determinations recorded by nurses over 30 days in two hospital wards.
- Assessment of data completeness, time accuracy, and glucose concentration accuracy during manual transcription.
Main Results:
- A significant percentage of results were missed (12.1%) or inaccurately recorded (7.2% for time, 3.2% for concentration).
- Despite high error rates in data transcription, no adverse patient events were directly attributed to these POCT-related errors.
Conclusions:
- The post-analytical phase of blood glucose POCT is prone to frequent transcription errors.
- While transcription errors are common, current evidence suggests they did not lead to adverse events in this study, highlighting a need for improved data management protocols.
Related Concept Videos
Errors occurring during blood pressure monitoring
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
Hyperglycemia
Hyperglycemia is an abnormally high blood glucose level. It is diagnosed by fasting glucose ≥126 mg/dL, 2-hour oral glucose tolerance test (or OGTT) ≥200 mg/dL, random glucose ≥200 mg/dL with symptoms, or HbA1c ≥6.5%. However, HbA1c results may be unreliable in certain conditions, such as anemia or hemoglobinopathies, and the diagnosis should be confirmed unless classic symptoms are present. Postprandial hyperglycemia is typically considered significant when glucose levels exceed 180 mg/dL two...
Systematic Error: Methodological and Sampling Errors
In the case of systematic errors, the sources can be identified, and the errors can be subsequently minimized by addressing these sources. According to the source, systematic errors can be divided into sampling, instrumental, methodological, and personal errors.
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Hypoglycemia and Glucagon
Without prolonged fasting, healthy individuals maintain blood glucose levels above 3.5 mM due to a well-adapted neuroendocrine counterregulatory system that effectively prevents acute hypoglycemia, a potentially life-threatening condition. The primary clinical scenarios for hypoglycemia encompass diabetes treatment, inappropriate production of endogenous insulin or insulin-like substances by tumors, and the use of glucose-lowering agents in non-diabetic individuals. Notably, hypoglycemia in the...
SBAR II: Application of SBAR
SBAR is an effective communication tool used by healthcare professionals to communicate patient information accurately. SBAR stands for Situation, Background, Assessment, and Recommendation. For a better understanding, an example is given below.
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Amperometry: Overview
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...