Day-by-day variability of spontaneous baroreflex sensitivity measurements: implications for their reliability in
Roberto Maestri1, Grzegorz Raczak, Antoni Torunski
1Department of Cardiology and Biomedical Engineering, S. Maugeri Foundation-IRCCS, Scientific Institute of Montescano, Montescano, Pavia, Italy. roberto.maestri@fsm.it
Objective:
To assess day-by-day variability of spontaneous baroreflex sensitivity (BRS) measurements, providing implications for their reliability in clinical and research studies.
Methods:
Forty-four healthy volunteers and 57 patients with previous myocardial infarction (MI) underwent an 8 + 8 min (spontaneous + paced breathing) recording of ECG and noninvasive arterial pressure on two consecutive days. BRS was computed according to the sequence method (BRS_seq), the original and modified transfer function method (BRS_TF and BRS_TF(mod)) and the alpha method (BRS_alphaLF and BRS_alphaHF). Absolute and relative reliability were assessed by the 95% limits of random variation (LoV) and by the intraclass correlation coefficient (ICC), respectively. The sample size needed to detect a clinically relevant change was also estimated.
Results:
In healthy volunteers during spontaneous breathing, BRS_seq, BRS_TF, BRS_alphaLF and BRS_alphaHF could not be measured in 18, 3, 2 and 2% of recordings, respectively. By definition, BRS_TF(mod) could always be measured. The 95% LoV indicated that individual day-by-day changes may range from -50% to +101% for BRS_TF(mod) (best case) and from -58% to +135% for BRS_alphaHF (worst case). The ICC ranged from 0.70 (BRS_seq) to 0.76 (BRS_TF(mod)). The sample size varied from 56 (BRS_TF(mod)) to 80 (BRS_seq). In MI patients, measurability was lower whereas reliability indexes were similar. Results during paced breathing were similar.
Conclusion:
Day-by-day variability should be taken into account when using spontaneous BRS measurements to detect treatment effects in individual patients. The observed substantial to good relative reliability, as assessed by the ICC, indicates that spontaneous BRS measurements are suitable to detect differences between individuals, which is a prerequisite for proper diagnosis and prognosis.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...