Validation of the visocor HM40 wrist blood pressure measuring device according to the International Protocol
Francesca Dorigatti1, Elisa Bonso, Francesca Saladini
1Department of Clinical and Experimental Medicine, University of Padova, Padua, Italy.
Abstract:
The objective of this study was to determine the accuracy of the UEBE visocor HM40 device for blood pressure measurement at the wrist, tested according to the requirements of the International Protocol of the European Society of Hypertension (ESH). Device evaluation was performed in 33 patients whose age and blood pressure were within the intervals required by the ESH protocol. Their mean +/- SD age was 53.2 +/- 15.5 years (range 30-85 years), systolic blood pressure (SBP) was 142.8 +/- 21.8 mmHg (range 108-178 mmHg), diastolic blood pressure (DBP) was 87.0 +/- 15.4 mmHg (range 62-112 mmHg), and wrist circumference was 18.7 +/- 2.7 cm (range 15.5-21.5 cm). During the measurements, which were performed in the supine position, the patient's wrist was kept extended at the heart level with a support under the forearm. In total, 45 measurements were available for analysis in the first phase of the validation process, and 99 measurements in the second phase. The visocor HM40 passed all three phases of the ESH protocol for SBP and DBP. Mean blood pressure differences for the visocor HM40 monitor (device-observer) were -2.0 +/- 5.0 mmHg for SBP and -1.7 +/- 5.3 mmHg for DBP, respectively. These data show that the UEBE visocor HM40 wrist monitor met the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.