Laparoscopic retrieval of perforated intrauterine device
1Department of Obstetrics/Gynaecology, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria. jikechebelu@yahoo.com
Abstract:
We present a case of successful laparoscopic retrieval of a perforated intrauterine device (Lippes loop). The Lippes loop was inserted after manual intrauterine adhesiolysis as a treatment of uterine synaechia presenting as secondary amenorrhoea of 20 months duration. The uterine perforation in this patient did not occur at the time of insertion but possibly during the attempt at transcervical removal of the missing IUD by manipulation with the retrieval hook. Double puncture laparoscopic technique under ketamine general anaesthesia was performed to remove the IUD without complication and patient went home the same day.