Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Quantitative assessment of left atrial volume by electrocardiographic-gated contrast-enhanced multidetector computed
Amir A Mahabadi1, Bharat Samy, Sujith K Seneviratne
1Cardiac MR PET CT Program, Department of Radiology and Division of Cardiology, Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114, USA.
Background:
Left atrial (LA) volume is a predictor of cardiovascular events. Information on LA volume is available on contrast-enhanced electrocardiogram (EGC)-gated multidetector computed tomography (MDCT) scans.
Objective:
To assess interobserver and intraobserver reproducibility of 3-dimensional threshold-based volume (3DTV) and 2-dimensional (2D) measurements for the assessment of LA volumes with contrast-enhanced cardiac 64-slice MDCT.
Methods:
Contrast-enhanced 64-slice MDCT (0.6-mm slice thickness, 120 kVp, 850 mAseff) was performed in 96 consecutive subjects (mean age 52 years; 48% women) as a subset of the Rule Out Myocardial Infarction using Computer Assisted Tomography trial. Two observers independently measured maximal (LAV(max)) and minimal (LAV(min)) LA volumes with (1) a modified Simpson's method (3DTV) based on delineation of LA areas in axial slices and (2) estimated LA volumes typically used in 2D echocardiography (area length and prolate ellipse). Interobserver and intraobserver reproducibility for each method as well as correlations between the methods were calculated.
Results:
Interobserver (n = 96) and intraobserver (n = 20) variability was significantly lower for 3DTV (8%) than for area length (13%; P < 0.001) or prolate ellipse (16%; P < 0.001). 2D-based measurements rendered significantly lower LA volumes than did 3DTV (area length: -17% and -22%; prolate ellipse: -43% and -46% for LAV(max) and LAV(min), respectively; P < 0.001 for all). By 3DTV, mean LA volume was 90.4 +/- 24.5 mL for LAV(max) and 52.5 +/- 17.6 mL for LAV(min).
Conclusion:
ECG-gated contrast-enhanced cardiac MDCT offers volumetric assessment of LA volume with excellent reproducibility without additional contrast administration or radiation exposure. 3D measures of LA volume are more reproducible and render larger volumes than 2D-derived estimates, typically used in echocardiography.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Cardiac Catheterization III: Left Heart Catheterization
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT