Related Experiment Video
Updated: Jun 24, 2026

Trabecular Bone Microarchitecture Evaluation in an Osteoporosis Mouse Model
Published on: September 8, 2023
Trabecular bone structure analysis in the osteoporotic spine using a clinical in vivo setup for 64-slice MDCT
Ahi S Issever1, Thomas M Link, Marie Kentenich
1Department of Radiology, Charite' Campus Mitte, Universitaetsmedizin Berlin, Berlin, Germany. ahi-sema.issever@charite.de
Abstract:
Assessment of trabecular microarchitecture may improve estimation of biomechanical strength, but visualization of trabecular bone structure in vivo is challenging. We tested the feasibility of assessing trabecular microarchitecture in the spine using multidetector CT (MDCT) on intact human cadavers in an experimental in vivo-like setup. BMD, bone structure (e.g., bone volume/total volume = BV/TV; trabecular thickness = Tb.Th; structure model index = SMI) and bone texture parameters were evaluated in 45 lumbar vertebral bodies using MDCT (mean in-plane pixel size, 274 microm(2); slice thickness, 500 microm). These measures were correlated with structure measures assessed with microCT at an isotropic spatial resolution of 16 microm and to microfinite element models (microFE) of apparent modulus and stiffness. MDCT-derived BMD and structure measures showed significant correlations to the density and structure obtained by microCT (BMD, R(2) = 0.86, p < 0.0001; BV/TV, R(2) = 0.64, p < 0.0001; Tb.Th, R(2) = 0.36, p < 0.01). When comparing microCT-derived measures with microFE models, the following correlations (p < 0.001) were found for apparent modulus and stiffness, respectively: BMD (R(2) = 0.58 and 0.66), BV/TV (R(2) = 0.44 and 0.58), and SMI (R(2) = 0.44 and 0.49). However, the overall highest correlation (p < 0.001) with microFE app. modulus (R(2) = 0.75) and stiffness (R(2) = 0.76) was achieved by the combination of QCT-derived BMD with the bone texture measure Minkowski Dimension. In summary, although still limited by its spatial resolution, trabecular bone structure assessment using MDCT is overall feasible. However, when comparing with microFE-derived bone properties, BMD is superior compared with single parameters for microarchitecture, and correlations further improve when combining with texture measures.
More Related Videos
09:36Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
Published on: March 14, 2018
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017