Related Experiment Video
Updated: Jun 24, 2026

Using Deuterium Oxide as a Non-Invasive, Non-Lethal Tool for Assessing Body Composition and Water Consumption in Mammals
Published on: February 20, 2020
Laser-based human breath analysis: D/H isotope ratio increase following heavy water intake
Richard Bartlome1, Markus W Sigrist
1Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland.
Abstract:
Following the ingestion of only 5.1 mL of D2O, a mid-infrared laser spectrometer determines the D/H isotope ratio increase in exhaled water vapor for the first time, to the best of our knowledge. This increase is still detectable several weeks after the heavy water intake. Collected breath samples are directly transferred into a high-temperature multipass cell operated at 373 K. No breath sample preparation is required. Aside from the capability to hinder unwanted condensation, measurements at elevated temperatures offer other advantages such as a lower temperature dependence of the delta value or the possibility to vary the intensity of absorption lines. We lay the foundation for many laser-based clinical applications. As an example, we measure a total body water weight of 55.2%+/-1.8% with respect to the total body weight, in agreement with the normal value of the male population.