Related Experiment Video
Updated: Jun 24, 2026

Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Impact of wastewater fouling on contact angle
1NASA-Johnson Space Center, Houston, TX 77058, USA. evan.a.thomas@nasa.gov
Abstract:
Capillary dependent systems are highly influenced by surface fouling and may degrade as material surface properties change. In anticipation of a spacecraft microgravity fluids management system exposed to highly variable wetting conditions, the impact of urine wastewater fouling on capillary contact angle was examined. The results indicate that, in general, surface fouling can decrease the contact angle when crystalline structures or biofilms form. Small crystalline growth on the order of 10 microm can lower advancing contact angles theta(adv) by approximately 30 degrees, while biofilm growth can lower it by approximately 15 degrees. Vacuum drying of fouled surfaces increased theta(adv) by about 8 degrees, and defects greater in height than 5% of the capillary length increased theta(adv) by approximately 30 degrees. These trends may indicate that promotion of wastewater fouling may improve the performance of capillary dependent fluids management systems. These results may also influence terrestrial technologies, including medical catheters and sustainable wastewater treatment systems exposed to wastewater fouling.
Related Concept Videos
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive force...
Microbial Wastewater Treatment
Coagulation