Karin Blijdorp1, Karlien Cransberg, Enno D Wildschut
1Department of Intensive Care, Erasmus MC Sophia Children's Hospital, Dr Molewaterplein 60, 3015 GJ Rotterdam, The Netherlands.
Introduction:
Extracorporeal membrane oxygenation is a supportive cardiopulmonary bypass technique for patients with acute reversible cardiovascular or respiratory failure. Favourable effects of haemofiltration during cardiopulmonary bypass instigated the use of this technique in infants on extracorporeal membrane oxygenation. The current study aimed at comparing clinical outcomes of newborns on extracorporeal membrane oxygenation with and without continuous haemofiltration.
Methods:
Demographic data of newborns treated with haemofiltration during extracorporeal membrane oxygenation were compared with those of patients treated without haemofiltration in a retrospective 1:3 case-comparison study. Primary outcome parameters were time on extracorporeal membrane oxygenation, time until extubation after decannulation, mortality and potential cost reduction. Secondary outcome parameters were total and mean fluid balance, urine output in mL/kg/day, dose of vasopressors, blood products and fluid bolus infusions, serum creatinin, urea and albumin levels.
Results:
Fifteen patients with haemofiltration (HF group) were compared with 46 patients without haemofiltration (control group). Time on extracorporeal membrane oxygenation was significantly shorter in the HF group: 98 hours (interquartile range (IQR) = 48 to 187 hours) versus 126 hours (IQR = 24 to 403 hours) in the control group (P = 0.02). Time from decannulation until extubation was shorter as well: 2.5 days (IQR = 0 to 6.4 days) versus 4.8 days (IQR = 0 to 121.5 days; P = 0.04). The calculated cost reduction was euro5000 per extracorporeal membrane oxygenation run. There were no significant differences in mortality. Patients in the HF group needed fewer blood transfusions: 0.9 mL/kg/day (IQR = 0.2 to 2.7 mL/kg/day) versus 1.8 mL/kg/day (IQR = 0.8 to 2.9 mL/kg/day) in the control group (P< 0.001). Consequently the number of blood units used was significantly lower in the HF group (P< 0.001). There was no significant difference in inotropic support or other fluid resuscitation.
Conclusions:
Adding continuous haemofiltration to the extracorporeal membrane oxygenation circuit in newborns improves outcome by significantly reducing time on extracorporeal membrane oxygenation and on mechanical ventilation, because of better fluid management and a possible reduction of capillary leakage syndrome. Fewer blood transfusions are needed. All in all, overall costs per extracorporeal membrane oxygenation run will be lower.
Related Concept Videos
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...