Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Museum Fish Collections and DNA Barcoding Reveal the Invasion History of the Zoonotic Yellow Grub Parasite (<i>Clinostomum sinensis</i>) in Taiwan's Rivers.

Zoological studies·2026
Same author

Chromosome-Level Genome Assembly of the Japanese Zacco platypus for Comparative Genomics.

Scientific data·2025
Same author

Graphitized Mesoporous Nanocomposites Enables Matrix-Free Soft Ionization for Multi-Class Drug Screening.

Small (Weinheim an der Bergstrasse, Germany)·2025
Same author

A new species of Paratanakia (Teleostei: Cyprinidae) from Guangdong, China.

Zootaxa·2025
Same author

A new Calamiana species (Teleostei: Gobiidae) from brackish waters of northern Taiwan.

Zootaxa·2025
Same author

Chromosome-Level Genome Assembly of the Loach Goby Rhyacichthys aspro Offers Insights Into Gobioidei Evolution.

Molecular ecology resources·2025
Same journal

Stereo-sensitive modelling of gas chromatographic retention indices of mono-cycloalkanes in jet fuel range.

Journal of chromatography. A·2026
Same journal

Approaches to using retention indices with coupled column pressure tuning in gas chromatography.

Journal of chromatography. A·2026
Same journal

MOF-supported surface-imprinted polymer for hazard governance of aristolochic acids in herbal matrices: A safety-control strategy supported by multiscale simulations.

Journal of chromatography. A·2026
Same journal

Portable cold-assisted head-space solid-phase microextraction coupled with GC-MS/MS for sensitive determination of trace polychlorinated naphthalenes in water.

Journal of chromatography. A·2026
Same journal

Characterization of phosphorous impurities originating from the synthesis of Sarin.

Journal of chromatography. A·2026
Same journal

Extraction and chromatographic purification of purpurin: A scalable approach using modified dry column vacuum chromatography.

Journal of chromatography. A·2026
See all related articles

Related Experiment Video

Updated: Jun 24, 2026

Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
09:34

Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry

Published on: September 20, 2016

Dynamic headspace time-extended helix liquid-phase microextraction.

Shih-Pin Huang1, Pai-Shan Chen, Shang-Da Huang

  • 1Department of Chemistry, National Tsing Hua University, Hsinchu 30013, Taiwan.

Journal of Chromatography. A
|April 7, 2009
PubMed
Summary
This summary is machine-generated.

A new dynamic headspace time-extended helix liquid-phase microextraction (DHS-TEH-LPME) method enhances organochlorine pesticide extraction from water. This technique improves efficiency and detection limits for environmental analysis.

More Related Videos

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
09:19

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction

Published on: June 1, 2022

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
05:31

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool

Published on: May 25, 2021

Related Experiment Videos

Last Updated: Jun 24, 2026

Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
09:34

Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry

Published on: September 20, 2016

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
09:19

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction

Published on: June 1, 2022

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
05:31

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool

Published on: May 25, 2021

Area of Science:

  • Analytical Chemistry
  • Environmental Chemistry
  • Separation Science

Background:

  • Liquid-phase microextraction (LPME) is a rapid, cost-effective sample preparation technique.
  • Existing methods face limitations in extraction efficiency and solvent loss.

Purpose of the Study:

  • To introduce and validate a novel dynamic headspace time-extended helix liquid-phase microextraction (DHS-TEH-LPME) technique.
  • To improve the extraction efficiency and sensitivity for organochlorine pesticides (OCPs) in water samples.

Main Methods:

  • Developed DHS-TEH-LPME using a solvent cooling system to lower extraction temperature.
  • Optimized parameters including solvent type, agitation, time, temperature, and salt concentration.
  • Analyzed six OCPs in spiked water samples using gas chromatography (GC).

Main Results:

  • Achieved enrichment factors up to 2121-fold for OCPs.
  • Method detection limits (MDLs) ranged from 0.2 to 25 ng/l.
  • Demonstrated high linearity (R² ≥ 0.996) and excellent recoveries (>86%) in river water.

Conclusions:

  • The DHS-TEH-LPME technique offers a highly efficient and sensitive method for OCP analysis.
  • Lowering extraction temperature and increasing solvent volume significantly improve performance.
  • This method is suitable for trace-level pesticide determination in environmental water samples.