Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
Published on: April 29, 2011
Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness
Fabrice Vallée1, Jean Christophe M Richard, Arnaud Mari
1Pôle Anesthésie et Réanimation, Unité de Réanimation Polyvalente de Purpan, GRCB 48, Université Paul Sabatier, Toulouse, France. vallee.f@chu-toulouse.fr
Objective:
To evaluate the ability of DeltaPP/DeltaP [pulse pressure variations (DeltaPP) adjusted by alveolar pressure variations (DeltaP = Pplat-PEEPtot)] in predicting fluid responsiveness, to compare its accuracy to that of DeltaPP used alone and to evaluate the influence of tidal volume (Vt) on these two indices.
Design:
Prospective study.
Setting:
A 22-bed general intensive care unit (ICU).
Patients:
Eighty-four surgical or medical ventilated patients requiring fluid challenge.
Intervention:
A 6 ml/kg colloid fluid challenge in 30 min.
Measurements And Results:
Hemodynamic measurements taken before and after fluid challenge. Patients separated into responders and nonresponders according to a 15% increase in their cardiac output. Thirty-nine patients found to be responders and 45 nonresponders. DeltaPP/DeltaP and DeltaPP were both higher in responders than in nonresponders. DeltaPP/DeltaP was a better predictor of fluid responsiveness than PP, especially for patients ventilated with Vt > or = 8 ml/kg [area under the curve (AUC) 0.88 (0.77-0.98) versus 0.75 (0.60-0.89), P < 0.01)]. In this population DeltaPP/DeltaP higher than 0.9 predicted fluid response with positive predictive value of 87% and negative predictive value of 78%. Overall DeltaPP and DeltaPP/DeltaP reliability was poor for patients ventilated with Vt < 8 ml/kg [AUC 0.63 (0.45-0.81) and 0.72 (0.55-0.88), respectively].
Conclusion:
In this mixed ICU population PP adjusted by P is a simple index which outperforms DeltaPP for patients ventilated with Vt > or = 8 ml/kg. However, correcting DeltaPP by DeltaP still fails to predict fluid response reliably in patients ventilated with low tidal volume.
Related Concept Videos
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in pressure...