Related Experiment Video
Updated: Jun 24, 2026

Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
Published on: September 24, 2021
[Factors influencing development of atrial fibrillation after implantation of cardiac pacemaker for sinus node
Audrius Aidietis1, Jūrate Barysiene, Germanas Marinskis
1Center of Cardiology and Angiology, Clinics of Santariskes, Vilnius University Hospital, Santariskiu 2, Vilnius, Lithuania. audrius.aidietis@santa.lt
Objective:
The aim of this study was to evaluate factors influencing the success of atrial fibrillation treatment associated with the sick sinus syndrome after pacemaker implantation.
Methods And Results:
In 163 patients with sick sinus syndrome followed up after pacemaker implantation, statistical analysis showed that the recurrence of atrial fibrillation increased 2.8 times and 2.5 times when the left atrium or the right atrium, respectively, were increased by 1 cm (P=0.001). In addition, the recurrence of atrial fibrillation increased 2.5 times when the interventricular septum was thickened (P=0.007). Probability of atrial fibrillation recurrence was 2.73 times higher in the presence of grade II mitral regurgitation as compared to absent or grade I mitral regurgitation (P=0.029). The results of atrial fibrillation treatment did not significantly depend on age, gender, duration of atrial fibrillation symptoms, other cardiac structural changes, and concomitant noncardiac diseases.
Conclusions:
In patients with sick sinus syndrome, the effectiveness of atrial fibrillation treatment after pacemaker implantation is influenced by enlargement of the left and the right atria, increased interventricular septum thickness, and grade II mitral regurgitation. Evaluation of echocardiographic data before pacemaker implantation has prognostic value for determining the probability of maintenance of sinus rhythm.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism, and...
Dysrhythmias IV: Characteristics of Bradyarrhythmias

