Copper(II) complexes spread on an aqueous solution surface were studied by a polarized total-reflection X-ray absorption fine structure (TR-XAFS) technique. The polarized TR-XAFS spectra at the Cu-K edge for copper(II) porphyrins and copper(II) chlorophyllin in a monolayer were measured in situ at the air-water interface. The polarization dependences of X-ray absorption near-edge structure (XANES) involving a 1s-->4p(z) transition allowed us to estimate the molecular orientation and the local coordination structure around the copper(II) atom in the polarization plane selectively. The extended X-ray absorption fine structure (EXAFS) region of the polarized TR-XAFS spectra for the metal complexes present at the air-water interface was successfully analyzed for the first time. The relative coordination number for the copper center evaluated from the EXAFS analysis indicated larger values in the vertical polarization than in the horizontal one, in agreement with the standing-up molecular orientation at the air-water interface estimated from the XANES region.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
09:16X-ray Powder Diffraction in Conservation Science: Towards Routine Crystal Structure Determination of Corrosion Products on Heritage Art Objects
Published on: June 8, 2016
Related Concept Videos
Determination of Crystal Structures
Extraction: Advanced Methods
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...