Related Experiment Video
Updated: Jun 24, 2026

Monitoring the Reductive and Oxidative Half-Reactions of a Flavin-Dependent Monooxygenase using Stopped-Flow Spectrophotometry
Published on: March 18, 2012
A catalytic resonance fluorometry method for determination of hydroquinone and its applications
Guirong Li1, Guanghui Tan, Yunfu Liu
1College of Public Health, University of South China, Hengyang 421001, PR China. liguirong525@126.com
Abstract:
Pyronin Y (PY) has a strong resonance fluorescence in sulfuric acid medium. The characteristics of the resonance fluorescence spectra and the factors affecting the spectra were studied. A catalytic resonance fluorometry method for the determination of hydroquinone was proposed based on the catalytic effect of hydroquinone on the oxidation of PY by potassium bromate. The oxidation of PY resulted in the decrease of the resonance fluorescence intensity. The influences of several variables on the sensitivity were studied. At the optimized conditions, the decrease of the resonance fluorescence intensity was in proportion to the concentration of hydroquinone in the range of 4.42-1.60 x 10(3) microg l(-1), and the detection limit was 1.46 microg l(-1). The proposed method was applied successfully for the determination of trace hydroquinone in environment samples. The relative standard deviation was less than 3.90% and the recoveries were in the range of 95.2-104.0%.
Related Concept Videos
Oxidation of Phenols to Quinones
o-hydroxy phenols are oxidized to o-quinones and p-hydroxy phenols to p-quinones. Such redox reactions involve the transfer of two electrons and two protons. The reversible redox property is crucial in...
Photoluminescence: Applications
Measuring Reaction Rates