Radiation dose and image quality of prospective triggering with dual-source cardiac computed tomography
Ron Blankstein1, Amar Shah, Rodrigo Pale
1Department of Radiology and Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, USA. rblankstein@partners.org
Abstract:
Prospectively triggered (PT) cardiac computed tomography (CT), whereby radiation is administered only at a predefined phase of the cardiac cycle, has been shown to substantially decrease radiation dose. The aim of our study was to assess the use of this technique in a clinical population using dual-source cardiac CT. Of 312 consecutive patients referred for a dual-source cardiac computed tomographic examination, PT was used in 42 patients for whom, based on physician judgment, it was decided to minimize radiation, whereas retrospective gating was used for 188 patients (coronary artery bypass grafting and pulmonary vein studies were excluded). Kilovolt and milliampere per second were chosen for each patient based on assessment of body habitus and effective radiation dose was calculated. Analysis of nonevaluable vessels was based on clinical readings. For each study, image quality (IQ) was rated on a subjective IQ score and contrast-to-noise and signal-to-noise ratios were calculated. Of the 42 PT examinations (mean age 44.3 years, body mass index 27.8 kg/m(2), 62% men), 28 were referred for coronary evaluation, 11 for aortic disease with/without coronaries, and 3 for other reasons (i.e., suspected mass and congenital disease). Average heart rate was 64.5 beats/min. Average radiation dose of all 42 PT scans was 3.2 +/- 1.6 vs 13.4 +/- 7.8 mSv for the 188 non-PT scans. There was no significant difference in IQ score and contrast-to-noise and signal-to-noise ratios between the 2 groups. Furthermore, the incidence of limited right coronary artery evaluation and of limitations related to right coronary artery motion did not differ between PT and non-PT scans. In conclusion, in selected patients, prospective triggering with dual-source cardiac CT is feasible and results in a dramatic decrease of radiation dose without compromising IQ. Future advances in cardiac CT may further improve this technique, thus allowing for wider use.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET