Determination of ammonium and organic bound nitrogen by inductively coupled plasma emission spectroscopy
A M Y Jaber1, N A Mehanna, S M Sultan
1King Fahd University of Petroleum & Minerals, Chemistry Department, Dhahran 31261, Saudi Arabia. amjaber@kfupm.edu.sa
Abstract:
The continuous flow sample introduction technique with a hydride generator system in conjunction with an inductively coupled plasma emission spectrometer (ICP-AES-HG), is used in this study for quantitative determination of ammonium and organic bound nitrogen in aqueous and solid samples. Ammonia vapor released from ammonium salt after treatment with concentrated NaOH is transferred by argon to plasma for detection at 174.273 nm using axial argon plasma mode. The calibration curves were linear within a range of 25-1000 mg L(-1)N as ammonium molybdate with correlation coefficients of better than 0.99 and limits of detection of about 10-25mg L(-1)N. The percent recovery of N (25-500 mg L(-1)N) in soft (distilled) water and high salt content (1.7 mol L(-1) NaCl) matrices was found to be in the range of about 97-102% with %RSD in the range of 4.6-0.62. The sensitivity, limit of detection, and blank contribution from the atmospheric nitrogen, were tremendously improved in this method compared with the available ICP-AES spray chamber counterpart. Furthermore, the ICP-AES-HG method gave results for real samples (soil, fertilizer, waste water) containing about 50-1800 mg L(-1)N in good agreement with those obtained by the standard Kjeldahl method. No statistical differences at the 95% confidence level on applying the t-test were observed between the values obtained by the two methods. Thus, the ICP-AES-HG method is reliable and faster than the conventional tedious Kjeldahl method, superior to the ICP-AES spray chamber method, and almost free from matrix interference which is usually a critical factor in atomic emission spectroscopic techniques.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
07:14Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inorganic Nitrogen Assimilation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Mass Spectrometry of Amines
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Instrumentation