Dispersive liquid-liquid microextraction combined with gas chromatography-electron capture detection for the
Jia Hu1, Lingyan Fu, Xinna Zhao
1Department of Chemical Engineering, Zhejiang University, Hangzhou, Zhejiang 310027, China.
Abstract:
In this article, dispersive liquid-liquid microextraction (DLLME) and gas chromatography-electron capture detection (GC-ECD) were presented for the extraction and determination of five polychlorinated biphenyls (PCBs) in soil samples. Acetone was used as extraction solvent for the extraction of PCBs from soil samples. In DLLME, the target analytes in the extraction solvent were rapidly transferred from the acetone extract to chlorobenzene when the extraction process began. The main advantages of this method are quick speed, high enrichment factor, high recovery and good repeatability. Under the optimum conditions, the method yields a linear calibration curve in the concentration range from 2 to 2000 microg kg(-1)for PCB 52, and 0.4 to 400 microg kg(-1) for other target analytes. Coefficients of correlation (r(2)) ranged from 0.9993 to 0.9999. The repeatability was tested by spiking soil samples at a concentration level of 10 microg kg(-1) for PCBs. The relative standard deviations (RSDs, n=11) varied between 2.2% and 6.4%. The limits of detection (LODs), based on signal-to-noise (S/N) of 3, were between 0.20 and 0.50 microg kg(-1). The relative recoveries of the five PCBs from soil S1, S2 and S3 at spiking levels of 10, 20 and 50 microg kg(-1) were in the range of 88.70-103.8%, 82.50-106.3% and 82.30-113.6%, respectively. Therefore, DLLME combined with GC-ECD can be successfully applied for the determination of trace PCB residues in real soil samples.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: