The Use of a β-lactamase-based Conductimetric Biosensor Assay to Detect Biomolecular Interactions
Published on: February 1, 2018
Challenges of electrochemical impedance spectroscopy in protein biosensing
A Bogomolova1, E Komarova, K Reber
1Fractal Systems Inc., 108 Fourth Street, Belleair Beach, Florida 33786, USA. abogomol@hotmail.com
Abstract:
Electrochemical impedance spectroscopy (EIS) measurement, performed in the presence of a redox agent, is a convenient method to measure molecular interactions of electrochemically inactive compounds taking place on the electrode surface. High sensitivity of the method, being highly advantageous, can be also associated with nonspecific impedance changes that could be easily mistaken for specific interactions. Therefore, it is necessary to be aware of all possible causes and perform parallel control experiments to rule them out. We present the results obtained during the early stages of aptamer-based sensor development, utilizing a model system of human alpha thrombin interacting with a thiolated DNA aptamer, immobilized on gold electrodes. EIS measurements took place in the presence of iron ferrocyanides. In addition to known method limitations, that is, inability to discriminate between specific and nonspecific binding (both causing impedance increase), we have found other factors leading to nonspecific impedance changes, such as: (i) initial electrode contamination; (ii) repetitive measurements; (iii) additional cyclic voltammetry (CV) or differential pulse voltammetry (DPV) measurements; and (iv) additional incubations in the buffer between measurements, which have never been discussed before. We suggest ways to overcome the method limitations.
More Related Videos
08:41Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation
Published on: October 10, 2018
09:30Analyzing Dynamic Protein Complexes Assembled On and Released From Biolayer Interferometry Biosensor Using Mass Spectrometry and Electron Microscopy
Published on: August 6, 2018
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.