A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Polymer-functionalized single-walled carbon nanotubes as a novel sol-gel solid-phase micro-extraction coated fiber
Weiya Zhang1, Yin Sun, Caiying Wu
1College of Chemistry and Molecular Science, Wuhan University, Wuhan, 430072, China.
Abstract:
Single-walled carbon nanotubes (SWNTs) were functionalized with a hydroxyl-terminated silicone oil (TSO-OH). It is synthesized by the reactions of carbonyl chloride groups on the surface of SWNTs and hydroxyl groups of silicone oil (TSO-OH). The functionalized product SWNTs-TSO-OH was first used as precursor and selective stationary phase to prepare the sol-gel derived poly(SWNTs-TSO-OH) solid-phase microextraction (SPME) fiber for determination of polybrominated diphenyl ethers (PBDEs) in water samples. The possible major reaction of the sol-gel coating process was discussed and confirmed by IR spectra, Raman spectroscopy, and scanning electron microscopy. Some parameters of SPME fiber for the determination of PBDEs were investigated by headspace SPME/gas chromatography with electron-capture detection (HS-SPME/GC-ECD). Compared with the commercial SPME fiber, the new coated fiber showed higher extraction efficiency to PBDEs, better thermal stability (over 340 degrees C), and longer life span (over 200 times). All of these advantages are mainly due to the incorporation of SWNTs, which enhanced the pi-pi interaction with PBDEs and increased the surface area of extraction in contact with the sample. Moreover, the sol-gel coating technology additionally provided the porous structure of the 3-D silica network and the strong chemical binding provided which also will improve the extraction efficiency. Under optimized conditions, the method detection limits for seven PBDEs were 0.08-0.8 ng/L (S/N = 3) and the precision (RSD, n = 5) was 2.2-7.5% at the 50 ng/L level. The linearity of the developed method is in the range of 5-500 ng/L with coefficients of correlation greater than 0.995. The developed method was successfully applied for the analysis of trace PBDEs in reservoir water and wastewater samples. The recoveries obtained at spiking 50 ng/L were between 74% and 109% (n = 5) for PBDEs in water samples.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...