Related Experiment Video
Updated: Jun 24, 2026

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
A new spectrofluorimetric method for determination of trace amounts histamine in human urine and serum
Qian Peng1, Jixiang He, Chongqiu Jiang
1College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, People's Republic of China.
Abstract:
A new spectrofluorimetric method was developed for the determination of trace amounts of histamine in human urine and serum samples. In NaAc-HAc buffer solution of pH 4.0, histamine can react with the acetylacetone-formaldehyde system to produce a fluorescent derivative which emits yellow-green fluorescence at 476 nm, according to the Hantzsch reaction, and the enhanced fluorescence intensity is in proportion to the concentration of histamine. Optimum conditions for the determination of histamine were also investigated. The dynamic range and detection limit for the determination of histamine is 5.96 x 10(-8)-1.50 x 10(-5 )mol/L and 4.35 x 10(-8)mol/L, respectively. This method is practical and can be successfully applied to determination of histamine in human urine and serum samples. A proposal of the reaction pathway is suggested.