Related Experiment Video
Updated: Jun 23, 2026

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Tissue oxygenation index measured using spatially resolved spectroscopy correlates with changes in cerebral blood
Flora Y Wong1, Makoto Nakamura, Theodora Alexiou
1Ritchie Centre for Baby Health Research, Monash University, 246 Clayton Road, Clayton, VIC 3168, Australia.
Background/Objective:
Abnormal cerebral haemodynamics in very preterm infants undergoing neonatal intensive care have been associated with adverse outcome, but cerebral blood flow (CBF) is difficult to assess at the cotside. Spatially resolved spectroscopy (SRS) continuously measures cerebral tissue oxygen saturation expressed as tissue oxygenation index (TOI, %), and TOI would reflect changes in CBF with constant cerebral metabolic demand. We aimed to evaluate the relationship between simultaneous measurements of CBF (Transonic System) and TOI (Hamamatsu NIRO-200) in newborn lambs (n = 8). We hypothesised that alterations in CBF of different magnitudes and frequencies would be reflected as changes of TOI in both time domain and frequency domain analyses.
Methods:
A silicon cuff positioned around the common brachiocephalic artery was inflated to induce 10-30% reductions in cerebral perfusion pressure so as to produce mild-to-moderate variations of CBF. Relationships between changes in CBF and TOI were evaluated in the time domain (Pearson correlation) and frequency domain (Coherence).
Results:
In time domain analysis, there was significant correlation between DeltaTOI (%) and DeltaCBF (%) (R2 = 0.69, P < 0.001). In frequency domain analysis, CBF-TOI coherence was > or = 0.5 at frequencies below 0.1 Hz, but <0.5 at higher frequencies.
Conclusions:
We conclude that overall TOI changes are concordant with CBF variations, when arterial oxygen saturation and cerebral oxygen consumption are constant. While TOI reflects CBF, it is more sensitive to variations of CBF of low frequency (<0.1 Hz) than to more rapid, higher frequency changes.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...