Electrolyte-induced ionization suppression and microcystin toxins: ammonium formate suppresses sodium replacement

William M Draper1, Dadong Xu, S Kusum Perera

  • 1California Department of Public Health, Sanitation & Radiation Laboratory, 850 Marina Bay Parkway, Richmond, California 94804, USA. william.draper@cdph.ca.gov

Analytical Chemistry
|April 21, 2009
PubMed

Insights

Electrolytes like sodium replacement ions interfere with microcystin (MC) analysis using LC-MS-MS. Adding ammonium formate (AF) buffer improves accuracy and specificity for MC detection by suppressing these interferences.

Area of Science:

  • Environmental Chemistry
  • Analytical Chemistry
  • Mass Spectrometry

Background:

  • Microcystins (MCs) are potent cyanotoxins requiring accurate quantification.
  • Electrospray ionization (ESI) mass spectrometry (MS) can be affected by electrolytes, leading to sodium replacement ions (SRI) in MC spectra.
  • These SRI phenomena complicate congener-specific LC-MS-MS detection and reduce quantitative reliability.

Purpose of the Study:

  • To investigate the impact of electrolytes on microcystin (MC) electrospray ionization (ESI) and quantitative LC-MS-MS.
  • To evaluate the effectiveness of ammonium formate (AF) as a buffer additive for improving MC analysis.
  • To elucidate mechanisms of electrolyte-induced ionization suppression in MC determination.

Main Methods:

  • Analysis of MCs using electrospray ionization (ESI) and liquid chromatography-tandem mass spectrometry (LC-MS-MS).
  • Electrolyte effects were studied using methanol-water gradients with acetic acid.
  • Pulse addition experiments were conducted to assess the impact of ammonium formate (AF) on SRI and adduct formation.

Main Results:

  • Sodium replacement ions (SRI) were observed in MC ESI spectra, impairing congener-specific detection and quantitative accuracy.
  • Ammonium formate (AF) addition significantly suppressed SRI in both +1 and +2 charge states.
  • AF enhanced MH(+) and MNH(4)(+) adducts, leading to increased specificity and improved transitions for MC quantification.

Conclusions:

  • Electrolytes, particularly sodium, interfere with MC analysis by forming SRI, degrading LC-MS-MS performance.
  • Post-column or mobile phase addition of ammonium formate (AF) effectively suppresses SRI and enhances desired adducts.
  • Utilizing a buffer electrolyte like AF is crucial for achieving improved specificity and analytical ruggedness in quantitative LC-MS-MS of microcystins.

Related Concept Videos

Qualitative Analysis03:46

Qualitative Analysis

For solutions containing mixtures of different cations, the identity of each cation can be determined by qualitative analysis. This technique involves a series of selective precipitations with different chemical reagents, each reaction producing a characteristic precipitate for a specific group of cations. Metal ions within a group are further separated by varying the pH, heating the mixture to redissolve a precipitate, or adding other reagents to form complex ions.
For instance, group IV...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Masking and Demasking Agents01:19

Masking and Demasking Agents

EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...
EDTA: Auxiliary Complexing Reagents01:26

EDTA: Auxiliary Complexing Reagents

EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...