Related Experiment Video
Updated: Jun 23, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Asymmetric spin-echo (ASE) spiral improves BOLD fMRI in inhomogeneous regions
Kimberly D Brewer1, James A Rioux, Ryan C N D'Arcy
1Institute for Biodiagnostics (Atlantic), National Research Council, Halifax, Nova Scotia, Canada.
Abstract:
Functional MRI (fMRI) is of limited use in areas such as the orbitofrontal and inferior temporal lobes due to the presence of local susceptibility-induced field gradients (SFGs), which result in severe image artifacts. Several techniques have been developed to reduce these artifacts, the most common being the dual-echo spiral sequences (spiral-in/out and spiral-in/in). In this study, a new multiple spiral acquisition technique was developed, in which the later spiral acquisitions are acquired asymmetrically with the peak of a spin-echo causing increased R(2)-weighting but matched R(2)'-weighting. This sequence, called asymmetric spin-echo (ASE) spiral, has demonstrated significant improvements in minimizing the signal loss and increasing the image quality as well as optimal blood-oxygen-level-dependent (BOLD)-weighting. The ASE spiral is compared to conventional spiral-out using both signal-to-noise ratio (SNR) and whole brain fMRI activation volumes from a breath-hold task acquired at 4 Tesla. The ASE dual spiral has exhibited SNR increases of up to 300% in areas where strong SFGs are present. As a result, the ASE spiral is highly efficient for recovering lost activation in areas of SFGs, as demonstrated by a 16% increase in the total number of activated voxels over the whole brain. Post spin-echo ASE spiral images have decreasing SNR due to R(2) signal losses, however the increase in R(2)-weighting leads to a higher percentage of signal changes producing ASE spiral images with equivalent contrast-to-noise ratio (CNR) for each echo. The use of this sequence allows for recovery of BOLD activation in areas of SFG without sacrificing the CNR over the whole brain.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
NMR Spectroscopy: Spin–Spin Coupling
Atomic Nuclei: Magnetic Resonance

