Related Experiment Video
Updated: Jun 23, 2026

An Open-Source Normothermic Perfusion System Designed for Research Scientists
Published on: July 18, 2025
Assessment of cadaveric organ viability during pulsatile perfusion using infrared imaging
Alexander M Gorbach1, David B Leeser, Hengliang Wang
1Bioengineering and Physical Science, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, MD, USA.
Abstract:
Assessment of pulsatile perfusion (PP) is limited to measurements of flow (V) and resistance (R). We investigated infrared (IR) imaging during PP as a means for precise organ assessment. IR was used to monitor 10 porcine kidneys during 18 hr of PP in an uncontrolled Donation after Cardiac Death model. An IR camera (Lockheed Martin) was focused on the anterior surfaces of the kidneys. The degree of temperature homogeneity was compared with standard measurements of V and R. IR thermal images correlated with V and R (R=0.92, P<0.001). IR detected an increase in homogeneity during PP by comparing standard deviation differences before and after PP (P=0.002), which was not evident by standard measurements of V and R. Finally, IR assessment allowed for measurement of dynamic changes in perfusion.

