A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
[Problematic of intra-abdominal pressure measurement]
1Evangelisches Krankenhaus, Göttingen-Weende, An der Lutter 24, 37075 Göttingen, Deutschland. Neumann@ekweende.de
Abstract:
Intra-abdominal hypertension (intra-abdominal pressure, IAP>12 mmHg) is observed in more than 30% of critically ill patients and is of major prognostic relevance. Unfortunately, clinical examination alone does not allow the IAP to be estimated with sufficient accuracy. Consequently, IAP monitoring should be considered if risk factors for intra-abdominal hypertension are present in order to enable early therapeutic intervention. A technically simple estimation of IAP is possible by intravesical pressure measurements. Alternatively, intragastric pressure can be measured continuously and IAP changes can be detected rapidly. In addition the development of IAP values over time can be appreciated more comprehensively compared to single snapshot-like measurements. The goal of IAP monitoring is not to keep the IAP below a certain threshold, but rather to establish a sufficient abdominal perfusion pressure [APP=mean arterial pressure (MAP)-IAP] of 50-60 mmHg. However, no data have yet been provided showing that the routine use of IAP monitoring and APP targeted therapy is able to improve the prognosis of critically ill patients.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure