Related Experiment Video
Updated: Jun 23, 2026

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Application of the AMPLATZER vascular plug in endovascular occlusion of dialysis accesses
Umut Ozyer1, Ali Harman, Cuneyt Aytekin
1Department of Radiology, Baskent University Faculty of Medicine, Ankara, Turkey. umut_ozyer@yahoo.com
Abstract:
The purpose of this study was to share our initial experience with the AMPLATZER Vascular Plug (AVP) in occluding dialysis accesses. Between January 2007 and October 2008, five patients with autogenous and one patient with prosthetic accesses were referred for endovascular occlusion owing to central venous obstruction (n = 4) and dialysis-associated steal syndrome (n = 2) leading to disabling complications. We used a single AVP in two patients, double AVPs in two patients, and double AVPs and n-butyl 2-cyanoacrylate in one patient with an autogenous access. Two coils were deployed between two AVPs to occlude the prosthetic graft. Immediate success was achieved in all patients, with no complications. Mean follow-up time was 13 months (range, 1-21 months) and none of the patients had experienced symptom recurrence as of the time of writing. The AVP allows simple, precise, and reliable dialysis access occlusion without significant complications when surgical ligation is not preferred. It can be used with other embolizing agents to provide occlusion in the case of failure.
Related Concept Videos
Hemodialysis I: Introduction
Hemodialysis II: Procedure and Complications