Related Experiment Video
Updated: Jun 23, 2026

Optimizing Mouse Urodynamic Techniques for Improved Accuracy
Published on: June 7, 2024
How painful is multichannel urodynamic testing?
Yakir Segev1, Talma Rosen, Ron Auslender
1Division of Urogynecology and Reconstructive Pelvic Surgery, Department of Obstetrics and Gynecology, Carmel Medical Center, Technion University Rappaport Faculty of Medicine, 7 Michal St, Haifa 34362, Israel. segevyakir@yahoo.com
Introduction And Hypothesis:
Multichannel urodynamic testing is considered to be the gold standard for evaluation of lower urinary tracts symptoms in women. The objective of this study was to assess the level of pain associated with this test.
Methods:
We reviewed charts of women who underwent multichannel urodynamic testing for lower urinary tract symptoms and recorded pain levels using a validated visual analog pain scale of 0-10 before, during, and 1.5 h after the test.
Results:
We identified 50 patients who underwent the test. Pain level increased mildly but significantly during the urodynamic test (1.24 +/- 0.9 vs 0.02 +/- 0.14 p < 0.001) and decreased thereafter (0.1 +/- 0.35, p < 0.001).
Conclusions:
Multichannel urodynamic testing is associated with a low but significant level of pain, which generally abates shortly after the procedure. No correlation seems to exist between the degree of pain and various clinical and pelvic floor parameters.
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography