Soliton ratchets in sine-Gordon systems with additive inhomogeneities

V Stehr1, P Müller, F G Mertens

  • 1Physikalisches Institut, Universität Bayreuth, 95440 Bayreuth, Germany. Vera.Stehr@Uni-Bayreuth.de

Related Concept Videos

Limits with Oscillating Discontinuities01:19

Limits with Oscillating Discontinuities

An oscillating discontinuity is a type of discontinuity in which a function’s values fluctuate infinitely often as the input approaches a particular point. Unlike jump discontinuities, where the function suddenly shifts between two values, or infinite discontinuities, where the function diverges without bound, an oscillating discontinuity arises from rapid back-and-forth variation. Because the function never stabilizes toward a single value, no finite limit exists at that point.One of the most...
Transmission-Line Differential Equations01:26

Transmission-Line Differential Equations

Transmission lines are essential components of electrical power systems. They are characterized by the distributed nature of resistance (R), inductance (L), and capacitance (C) per unit length. To analyze these lines, differential equations are employed to model the variations in voltage and current along the line.
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from the...
Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first column of the Routh...
Second Order systems II01:18

Second Order systems II

In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
If  ζ...
Poisson's And Laplace's Equation01:25

Poisson's And Laplace's Equation

The electric potential of the system can be calculated by relating it to the electric charge densities that give rise to the electric potential. The differential form of Gauss's law expresses the electric field's divergence in terms of the electric charge density.
Basic Discrete Time Signals01:16

Basic Discrete Time Signals

The unit step sequence is defined as 1 for zero and positive values of the integer n. This sequence can be graphically displayed using a set of eight sample points, showing a step function starting from n=0 and remaining constant thereafter.
The unit impulse or sample sequence is mathematically expressed as zero for all n values except at n=0, where it is one. The unit impulse sequence, denoted by δ(n), is the first difference of the unit step sequence, while the unit step sequence u(n) is the...