Conservation of the lateral electron momentum at a metal-semiconductor interface studied by ballistic electron

C A Bobisch1, A Bannani, Yu M Koroteev

  • 1Department of Physics, Center for Nanointegration Duisburg-Essen, University of Duisburg-Essen, 47048 Duisburg, Germany. christian.bobisch@uni-due.de

Related Concept Videos

Metal-Semiconductor Junctions01:24

Metal-Semiconductor Junctions

The contact of metal and semiconductor can lead to the formation of a junction with either Schottky or Ohmic behavior.
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The semiconductor's...
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fermi Level Dynamics01:12

Fermi Level Dynamics

The vacuum level denotes the energy threshold required for an electron to escape from a material surface. It is usually positioned above the conduction band of a semiconductor and acts as a benchmark for comparing electron energies within various materials.
Electron affinity in semiconductors refers to the energy gap between the minimum of its conduction band and the vacuum level and it is a critical parameter in determining how easily a semiconductor can accept additional electrons.
The work...
Biasing of Metal-Semiconductor Junctions01:27

Biasing of Metal-Semiconductor Junctions

Biasing metal-semiconductor junctions involves applying a voltage across the junction. Specifically, the metal is connected to a voltage source, while the semiconductor is grounded. This technique is essential for controlling the direction and magnitude of current flow in electronic devices, including diodes, transistors, and photovoltaic cells.
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
Transmission Electron Microscopy01:15

Transmission Electron Microscopy

In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Preparation of Samples for Electron Microscopy01:20

Preparation of Samples for Electron Microscopy

To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...