Related Experiment Video
Updated: Jun 23, 2026

Electric Cell-Substrate Sensing for Real-Time Evaluation of Metal-Organic Framework Toxicological Profiles
Published on: May 26, 2023
Direct toxicity assessment of toxic chemicals with electrochemical method
Chang Liu1, Ting Sun, Xiaolong Xu
1College of Sciences, Northeastern University, Shenyang 110004, China.
Abstract:
Electrochemical measurement of respiratory chain activity is a rapid and reliable screening for the toxicity on microorganisms. Here, we investigated in-vitro effects of toxin on Escherichia coli (E. coli) that was taken as a model microorganism incubated with ferricyanide. The current signal of ferrocyanide effectively amplified by ultramicroelectrode array (UMEA), which was proven to be directly related to the toxicity. Accordingly, a direct toxicity assessment (DTA) based on chronoamperometry was proposed to detect the effect of toxic chemicals on microorganisms. The electrochemical responses to 3,5-dichlorophenol (DCP) under the incubation times revealed that the toxicity reached a stable level at 60 min, and its 50% inhibiting concentration (IC50) was estimated to be 8.0 mg L(-1). At 60 min incubation, the IC50 values for KCN and As2O3 in water samples were 4.9 mg L(-1) and 18.3 mg L(-1), respectively. But the heavy metal ions, such as Cu2+, Pb2+ and Ni2+, showed no obvious toxicity on E. coli. With the exception of Hg2+, it showed 40.0 mg L(-1) IC50 value when E. coli was exposed to its solution for 60 min. The lower sensitivity of DTA for the heavy metal ions could be attributed to the toxicological endpoint and the experimental conditions used. All results suggest that the DTA is a sensitive, rapid and inexpensive alternative to on-site water and wastewater toxic analysis.
More Related Videos
Related Concept Videos
Electrogravimetric Analysis: Overview
To test the completeness of the...
Interfacial Electrochemical Methods: Overview
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...