Related Experiment Video
Updated: Jun 23, 2026

Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Hemodynamic and functional assessment of mechanical aortic valves using combined echocardiography and multidetector
Troy M LaBounty1, Prachi P Agarwal, Aamer Chughtai
1Department of Medicine, Division of Cardiology, Weill Cornell Medical College, New York, NY 1002, USA. tml9001@med.cornell.edu
Background:
Limitations are found in the ability of transthoracic echocardiography to evaluate mechanical aortic valve replacements (AVR). We evaluated the ability of combined echocardiography and computed tomography (CT) to enhance the hemodynamic and functional evaluation of AVR.
Methods:
We performed a retrospective evaluation of 41 consecutive patients with AVR (27 bileaflet, 14 single disc) and both transthoracic echocardiography and 64-detector electrocardiographic-gated CT. Each study was interpreted by 2 independent, blinded readers. The effective orifice area was compared with the corrected energy-loss coefficient area and the geometric orifice area. Patients with an elevated mean pressure gradient (>15 mm Hg) were assessed for potential abnormal findings, including patient-prosthesis mismatch, elevated cardiac index, valve dysfunction, significant regurgitation, or pressure recovery effect.
Results:
Significant differences (P<0.05) and moderate-to-high correlations (r=0.55-0.98) were observed between the effective orifice area (2.2+/-0.8 cm(2)), corrected energy-loss coefficient area (3.0+/-1.5 cm(2)), and geometric orifice area (3.6+/-0.9 cm(2)). At least one abnormality was observed in 7 of 25 patients with normal gradients and in 14 of 16 patients with elevated gradients (P<0.001). In 16 patients with elevated mean pressure gradient, a potential cause could be determined in 4 with echocardiography alone and in 14 patients with combined echocardiography and CT (P=0.001).
Conclusion:
CT aids in the interrogation of prosthetic valve function, enhancing evaluation for patient prosthesis mismatch, and correction for pressure recovery by the corrected energy-loss coefficient. CT is additive to the assessment of mechanical AVR with transthoracic echocardiography, and the combination permits a more complete assessment of both AVR function and hemodynamics.
More Related Videos
09:05Assessment of Cardiac Morphological and Functional Changes in Mouse Model of Transverse Aortic Constriction by Echocardiographic Imaging
Published on: June 21, 2016
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System V: CT
Mitral Stenosis II: Clinical features and Diagnostic Tests