Background And Purpose:
Fomites are increasingly being recognised as a source of hospital-acquired infection. We have therefore assessed tourniquets and exsanguinators for the presence of bacterial pathogens in 1 elective and 2 trauma orthopedic hospitals.
Material And Methods:
Swabs were taken prior to and after decontaminating these devices with 1 of 3 different cleaning modalities. These were then assessed for colony counts and organisms identified.
Results:
Bacteria commonly implicated in surgical site infections such as coagulase-negative staphylococci, Staphylococcus aureus and Proteus spp. were prevalent. We also found a resistant strain of Acinetobacter and Candida. Exsanguinators were the most heavily contaminated devices, and colony counts in the trauma hospitals were up to 400% higher than in the elective hospital. Alcohol- and non-alcohol-based sterile wipes were both highly effective in decontaminating the devices.
Interpretation:
Infectious organisms reside on the tourniquets and exsanguinators presently used in the orthopedic theater. These fomites may possibly be a source of surgical site infection. We have demonstrated a simple and effective means of decontaminating these devices between cases.
Insights
Tourniquets and exsanguinators in orthopedic settings harbor infectious bacteria, potentially causing hospital-acquired infections. Sterile wipes effectively decontaminate these critical surgical devices.
Area of Science:
- Infection control in healthcare settings
- Microbiology of medical devices
- Orthopedic surgery safety
Background:
- Fomites (contaminated inanimate objects) are recognized as a significant source of hospital-acquired infections.
- Orthopedic surgical instruments like tourniquets and exsanguinators can harbor pathogenic bacteria.
Purpose of the Study:
- To assess tourniquets and exsanguinators for bacterial pathogens in orthopedic hospitals.
- To evaluate the effectiveness of different decontamination methods on these devices.
Main Methods:
- Swabs were collected from tourniquets and exsanguinators before and after decontamination.
- Three distinct cleaning modalities were tested.
- Bacterial colony counts were determined, and organisms were identified.
Main Results:
- Prevalent bacteria included coagulase-negative staphylococci, Staphylococcus aureus, and Proteus spp.
- Acinetobacter strains and Candida were also detected.
- Exsanguinators showed higher contamination levels, particularly in trauma settings (up to 400% increase).
- Both alcohol-based and non-alcohol-based sterile wipes demonstrated high decontamination efficacy.
Conclusions:
- Tourniquets and exsanguinators harbor infectious organisms in orthopedic theaters.
- These fomites represent a potential source of surgical site infections.
- Simple and effective decontamination methods using sterile wipes are available.
Related Concept Videos
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Peripheral Artery Disease V: Postoperative Nursing Management
Aneurysm IV: Nursing Management
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis IV: Nursing Management